Manufacturer of Custom Temperature Sensors


Temperature & Pressure Solutions Made Easy
Phone: 858-573-0983 Fax: 858-573-0623
Email: sales@thermx.com

Home Page
About Us
Industries Served
Catalog Request
Contact Us

Available Products

Air Probes
Alumina Tubes
Autoclave Thermocouple
Carbon Dioxide
CO2 Transmitters
CO2 Handhelds

Calibration Dry Wells Calibration Baths
Cement 0n Thermocouple
Ceramic Tubes
Chart Recorders
Chillers
Chilled Mirrors

Connectors
Controllers
Data Loggers
Digital Thermometers
Extension Wire
Field Metrology Wells
Flowmeters
Flow Calibrators

Heaters
Humidity Chambers
Humidity Generators

Humidity Handhelds

Humidity Probe Calibrator
Humidity Sensors
Humidity Transmitters

Immersion Circulators
Indicators
Infrared Pyrometers
Mulite Tubes
Multipoint Thermocouples
Panel Jacks
Partlow Controllers
Partlow Recorders
Pressure Calibrators
Pressure Transducers
Pressure Transmitters

Protection Heads
Protection Tubes
Probes

Refrigerating/Heating
Circulators

%RH Probes
RTDs
RTD Probes

Rotronic
Solid State Relay
SSR

Surface Probes
Temperature Baths
Temperature Calibrators
Temperature Transmitters
Thermometers
Thermocouples
Thermocouple Probes
Thermocouple Scanner
Thermocouple Strip Panel
Thermocouple Wire
Thermistors
Thermistor Probes
Thermowells
Water Activity Aw
Wire and Cable
WIKA Pressure Transmitters
Validation Thermocouples
Water Baths
West Instruments


General Eastern Chilled Mirror Hygrometers

NIST Traceable

Contact ThermX Southwest at 800-284-3769
for Availability and Engineering Support.

Single Stage Chilled Mirror_ Two Stage Chilled Mirror

Optica Chilled Mirror Hygrometer

 

Single Stage
Chilled Mirror Sensor


Dual Stage
Chilled Mirror Sensor

 



General Eastern Optica Series Chilled Mirror Hygrometers

The Optica series chilled mirror hygrometers offer traceable humidity and temperature measurements for the connected generation. Now humidity reference data is accessible from anywhere, anytime within a browser over the internet or your intranet.

The Optica measures dew point temperature by regulating the temperature of a polished metal mirror by the use of optical feedback such that a constant mass of dew or frost is maintained. The temperature of the mirror is measured with a precise PRT and is by definition equal to the dew or frost point.

Dew/Frost Point Range: -35°C to 25°C
Dew/Frost Point Accuracy: Standard: ±0.2°C

A fundamental dewpoint measurement is a primary measurement used as a transfer standard for calibrating other humidity instruments and sensors. Chilled mirror hygrometers such as the GE General Eastern Optica Series are used in standards and metrology labs as well as in industrial applications where precise and repeatable humidity measurement and control is required. The inherent accuracy and long term stability provides many advantages over other types of humidity measurement technologies.

Applications:

Calibration labs
Process control
Clean rooms
Environmental test chambers
Precision HVAC monitoring and control
Fuel cells
Heat exchanger and refrigerant coil calorimeters
Thermal processing/heat treating
Semiconductor manufacturing
Storage areas
Pharmaceutical validation chambers
Engine test cells and emissions testing
Aircraft engines and turbines

OptiSonde
Bench Top or Wall Mount
Chilled Mirrors

OptiSonde

The GE General Eastern OptiSonde Chilled Mirror Hygrometer utilizes either a bench or wall mounted analyzer with a single or two-stage chilled mirror sensor and PRTD to display and transmit a variety of parameters, such as dew point, relative humidity, dry bulb, wet bulb, absolute humidity, volume ratio, and mass ratio, making the GE General Eastern OptiSonde chilled mirror hygrometer a flexible instrument for a wide variety of applications.

Applications

Environmental test chambers
Engine test cells
Clean rooms
Air conditioning and heat exchange coil testing
Metrology labs



General Eastern 1111H Single Stage Chilled Mirror

Sensing Element
Four-wire 1/3 Class A DIN 43760 RPT, 100 S@ 32°F (0°C)

Dew/Frost Point Accuracy
Standard: ±0.36°F (±0.2°C)
Optional:±0.27°F (±0.15°C)

Sensitivity: >0.05°F (>0.03°C)
Repeatability: ±0.09°F (±0.05°C)
Hysteresis: Negligible

Cooling Stages
Single stage thermoelectric cooling (TEC) module

Auxiliary Cooling
Not applicable

Depression
81°F (45°C) at 77°F (25°C) dry bulb and atmospheric pressure

Typical Measurement Range
5°F to 77°F (-15°C to 25°C) dew/frost point (Td) in air @77°F (25°C) and atmospheric
pressure. Equivalent to 5%to 100% RH



General Eastern D2 Two Stage Chilled Mirror

Sensing Element
Four-wire 1/3 Class A DIN 43760 RPT, 100 S@ 32°F (0°C)

Dew/Frost Point Accuracy
Standard: ±0.36°F (±0.2°C)
Optional: ±0.27°F (±0.15°C)

Sensitivity: >0.05°F (>0.03°C)
Repeatability: ±0.09°F (±0.05°C)
Hysteresis: Negligible

Cooling Stages
Two-stage TEC module

Auxiliary Cooling
Not applicable

Depression
117°F (65°C) at 77°F (25°C) and atmospheric pressure

Typical Measurement Range
31°F to 77°F (-35°C to 25°C) dew/frost point (Td) in air @77°F (25°C) and atmospheric pressure. Equivalent to 0.7%to 100% RH.

Humilab Humidity Generator

Humidity Calibration Chamber - Portable

The Humilab™ is a NIST traceable relative humidity generator and calibration chamber that is continuously monitored by a chilled mirror hygrometer and precision RTD. The system is water jacketed for thermal stability and facilitates cost-effective calibrations of humidity sensors, probes, transmitters, recorders and data loggers.

Precise: ±0.2% RH Stability Accurate: ±1% RH from 10 to 70% RH & ±1.5% RH from 70 to 90% RH.

The Humilab relative humidity generator and calibration chamber employs the time-proportioned divided flow method to generate relative humidity values from 10% to 90% RH. Unlike other humidity chambers that use secondary %RH sensors, pressure transducers, or wet/dry bulb temperature sensors, the Humilab has a built-in primary humidity reference standard. %RH is calculated from the fundamental chilled mirror dew point and platinum RTD temperature measurements. The chilled mirror sensor and RTD are in the same environment as the devices under test. The relative humidity is controlled, regulating a fraction of a constant flow of dry air through a saturator. The dry air is produced with an internal pump and desiccant cartridge. The air streams are temperature-conditioned and mixed to maintain the desired RH level in the test chamber.

Applications:

Calibration Labs
HVAC and BAS Transmitters
Pharmaceutical Instruments
% RH Data Loggers
% RH Recorders
Industrial Humidity Probes
Test Humidity Sensors
Metrological & RadioSonde Sensors