Available Products
Air
Probes
Alumina Tubes
Autoclave
Thermocouple
Carbon Dioxide
CO2 Transmitters
CO2 Handhelds
Calibration Dry Wells Calibration Baths
Cement
0n Thermocouple
Ceramic Tubes
Chart Recorders
Chillers
Chilled Mirrors
Connectors
Controllers
Data Loggers
Digital Thermometers
Extension Wire
Field Metrology Wells
Flowmeters
Flow Calibrators
Heaters
Humidity Chambers
Humidity Generators
Humidity Handhelds
Humidity Probe Calibrator
Humidity Sensors
Humidity Transmitters
Immersion
Circulators
Indicators
Infrared Pyrometers
Mulite Tubes
Multipoint
Thermocouples
Panel Jacks
Partlow Controllers
Partlow Recorders
Pressure
Calibrators
Pressure Transducers
Pressure Transmitters
Protection
Heads
Protection Tubes
Probes
Refrigerating/Heating
Circulators
%RH Probes
RTDs
RTD Probes
Rotronic
Solid State
Relay
SSR
Surface Probes
Temperature
Baths
Temperature
Calibrators
Temperature Transmitters
Thermometers
Thermocouples
Thermocouple Probes Thermocouple
Scanner
Thermocouple Strip Panel
Thermocouple Wire
Thermistors
Thermistor Probes
Thermowells
Water Activity Aw
Wire and Cable
WIKA Pressure Transmitters
Validation
Thermocouples
Water Baths
West Instruments
|

Water
Activity Aw Measurement
Contact ThermX
Southwest at 800-284-3769
for Availability and
Engineering Support.
ROTRONIC offers a comprehensive line of humidity instruments,
probes, and sensors for the measurement of relative humidity, dew point,
water activity, and other humidity parameters. ROTRONICs unique
HygroClip technology firmly establishes ROTRONIC as a leader in the development
of cutting edge technology for the measurement of humidity. HygroClip
technology includes an ASIC and microprocessor to handle all computations
necessary to provide an accurate humidity measurement. Combining the stable
digital electronics of the HygroClip with the most stable RH sensor available
provides accurate problem free measurements.
|
|
|
|
|
-
Stand alone system with ultra fast water activity
measurement of up to 4 product samples simultaneously.
-
AwQuick Mode - Accelerated water activity measurement
in typically 5 minutes.
-
AwE Mode: conventional water activity measurement
with automatic detection of equilibrium
-
Includes 2 sizes of sample holders and disposable
sample cups, humidity calibration standards.
-
Compatible with the HW4 software for the capture
of end values, live graph, data logging, etc.
-
HygroLab 3 bench-top meter accepts a large choice
of probes, suitable for the direct measurement of products in
bulk.
|
|
|
Rotronic
HP23-AW-14 Set
Portable system for measuring the water activity of up to 2 product
samples simultaneously:
- Perfect for the low budget laboratory and for production quality
control
- AwQuick Mode: ultra fast water activity measurement in typically
5 minutes
- AwE Mode: conventional water activity measurement with automatic
detection of equilibrium
- HP23 indicator accepts a large choice of probes for the measurement
of products in bulk and other applications
Set Contents:
- HP23-AW indicator
- HC2-AW probe for the measurement of product samples
- WP40 sample holder with depth reduction insert
- PS14: Pack of 100 disposable sample
cups (14mm deep) for powders, liquids and paste.
- 1 box each EA35 (35 %RH) and EA80 (80%RH) humidity calibration
standards
- Carrying case
|
|

Rotronic
HP23-AW-40 Set
|
Rotronic HP23-AW-40 Set
Portable system for measuring
the water activity of up to 2 product samples simultaneously:
- Perfect for the low budget laboratory and for production quality
control
- AwQuick Mode: ultra fast water activity measurement in typically
5 minutes
- AwE Mode: conventional water activity measurement with automatic
detection of equilibrium
- HP23 indicator accepts a large choice of probes for the measurement
of products in bulk and other applications.
Set Contents:
- HP23-AW indicator
- HC2-AW probe for the measurement of product samples
- WP40 sample holder with depth reduction insert
- PS40: Pack of 100 disposable sample
cups (40mm deep) for chunky samples.
- 1 box each EA35 (35 %RH) and EA80 (80%RH) humidity calibration
standards
- Carrying case
|
|
|
Rotronic
HC2-AW
|
|
|
|
|
|
Rotronic HC2-HP28
Hand-held probe for Measuring Powders,
Seeds and Materials in Bulk.
- Humidity measuring range: 0
100 %RH
- Temperature limits at sensor: -40
85 °C (-40
185
°F)
- Barrel: diameter 10 mm (0.4), length: 280 mm (11.0)
- Filter base (NSP-ME) and sintered steel filter cartridge (SP-S15)
- Probe cable length: 2 m (6.5 ft)
- Handgrip: POM, black -, barrel: stainless steel
|
|

Rotronic
PS1 Set
|
Rotronic PS1 Set
Measurement of the Humidity
and Temperature of Paper Stacks and Rolls.
The set includes:
- PS1 Indicator
- EGS Calibration Device
- Box of five 50 %RH Humidity Standards
- AC1115 Carrying Case
|
|
|
Rotronic
HygroLog HL-NT3
Humidity Temperature Data Logger
The HygroLog HL-NT humidity, dew point and temperature
data logger can be used with any of the HygroClip 2 probes. The
HL-NT can monitor up to 7 probes as well as up to two external
on/off contacts, such a a door contact.
When used together with the validated ROTRONIC HW4
software the HygroLog HL-NT data logger complies with FDA 21 CFR
part 11 regarding electronic data records and electronic signatures
(ERES).
The HW4 software can display the data from several data loggers
on multiple PCs and can centrally record on one of the PCs the
measurement data from several loggers. As a protection against
power outages and network failures, HW4 can be used to automatically
download the locally recorded data at regular intervals of time.
-
Relative humidity, temperature, dew point or
other calculated parameter
-
Measuring range: 0 to 100%RH and -100..200°C
/-148..392°F (with external probe)
-
Interchangeable humidity-temperature HygroClip
2 probe for fast and easy maintenance
-
Wide selection of probes to satisfy every application
-
Optional internal probe, protected against unauthorized
removal
-
Large recording capacity (depends on the size
of removable flash memory card)
-
Power supply: A/C adapter, backed up by a standard
or rechargeable 9 VDC battery
-
Full featured, Windows based ROTRONIC HW4 networking
software
-
HW4 software has optional OPC tags to export
data to any third-party OPC client application
Model Numbers:
- HL-NT2-D: data logger only (without internal HC2-S probe)
- HL-NT2-DP: includes internal HC2-S probe
- HL-NT3-D: data logger only (without internal HC2-S probe)
- HL-NT3-DP: includes internal HC2-S probe
|
|

Rotronic HL-NT
Docking Station
|
Rotronic
HL-NT
Data Logger: Docking Stations
- The HL-NT data logger requires a docking station for any
of the following:
- Mount the HL-NT data logger to a wall
- Logger can be secured to docking station with a padlock
- Place the HL-NT on the optional desk-top stand
- Use an external AC adapter to power the HL-NT
- Connect the HL-NT to a PC via a serial port (RS232), a USB port,
or
Ethernet - wired or wireless
- Connect up to 4 additional probes to the HL-NT
- Monitor up to two external contacts (relay, door, etc.)
- Connect up to 64 HL-NT data loggers together in a multi-dropped
arrangement (RS-485).
- Unlimited number of such networks
- Control up to 2 relay outputs
- Access the HL-NT from a web browser
|
|
HL-NT Data Logger:
Probe Options
|
Rotronic HL-NT Data Logger:
Probe Options

Call 800-284-3769
for Appliction Assistance
|
|
|
Rotronic
HL-20D Data Logger
Humidity Temperature Data
Logger
HL20 / HL21 Data Logger:
The HL20 and HL21 are accurate humidity temperature data loggers
designed for recording ambient conditions in indoor areas such as
research laboratories, high-tech manufacturing facilities and warehouses,
storage areas and containers for sensitive goods, museums, office
buildings, etc.
- Model HL20: records up to 20,000 pairs of relative humidity
and temperature values
- Model HL21: records up to 20,000 pairs of temperature values
- Internal sensors (no apparent probe)
- Optional LC display
- 0 to 100 %RH
- -10 to 60°C (14 to 140°F) - models with LC display:
0 to 50°C (32 to 122°F)
- Accuracy: ± 0.8 %RH and 0.2 °C
- Calibration and adjustment functions
Required Accessories:
- HW4 software for logger configuration, data download and data
analysis
- Cable AC 3006: Connects the data logger to a USB port of a PC
running the HW4 software
HW4 Standard Edition
- Single user, single instrument
HW4 Professional Edition
- Allows networking
- FDA / GAMP compliant
|
Contact ThermX
Southwest at 800-284-3769
for Availability
and Engineering Support.
|
|