Manufacturer of Custom Temperature Sensors


Temperature & Pressure Solutions Made Easy
Phone: 858-573-0983 Fax: 858-573-0623
Email: sales@thermx.com

Home Page
About Us
Industries Served
Catalog Request
Contact Us

Available Products

Air Probes
Alumina Tubes
Carbon Dioxide
CO2 Transmitters
CO2 Handhelds

Calibration Dry Wells Calibration Baths
Cement 0n Thermocouple
Ceramic Tubes
Chart Recorders
Connectors
Controllers
Data Loggers
Digital Thermometers
Extension Wire
Field Metrology Wells
Flowmeters
Flow Calibrators

Heaters
Humidity Handhelds
Humidity Sensors
Humidity Transmitters

Indicators
Infrared Pyrometers
Mulite Tubes
Multipoint Thermocouples
Panel Jacks
Partlow Recorders
Pressure Calibrators
Pressure Transducers
Pressure Transmitters

Protection Heads
Protection Tubes
Probes

%RH Probes
RTDs
RTD Probes

Solid State Relay
SSR

Surface Probes
Temperature Baths
Temperature Calibrators
Temperature Transmitters
Thermometers
Thermocouples
Thermocouple Probes
Thermocouple Scanner
Thermocouple Strip Panel
Thermocouple Wire
Thermistors
Thermistor Probes
Thermowells
Wire and Cable
WIKA Pressure Transmitters
Validation Thermocouples

Doric Instruments by VAS Engineering

 

 

 

 

 

 


Model 5000T-Digital Temperature Indicator and Miniature Datalogger

  • Image of Model 5000T Multi-channel Scanner Option with user selectable scan rates
  • Standard RS232 including powerful "Doric 5000 Viewer!" Software
  • Log data directly to your PC in 1 minute to 24 hour intervals
  • Dual Alarm Option with selectable HI/LOW or Deviation Setpoints
  • Captures MIN/MAX readings
  • Scaleable Analog Output Readings
  • User-friendly Alpha Numeric Menu
  • Made In USA
 

Programmable Digital Temperature Indicator and Data Logger

 

 

The Doric 5000 Series of single and multiple channel digital temperature indicators sets a new standard for performance, features, value and reliability. With built-in programmability, RS232 serial communications and powerful Windows-based software, the Doric 5000 is ideal for monitoring, testing and process control applications.

Complete configuration of the instrument can be quickly performed from the front panel, including sensor input type, sampling rate, limit settings, and resolution. Current value and min/max values can be selected for display from the front panel.

Thanks to its exclusive Viewer software, the Doric 5000 becomes a powerful PC-based data gathering, display and logging system. All front panel setup commands can be executed from your PC and all channel data, limit/alarm status and min/max values can be viewed simultaneously. In addition, you can label channel data, perform engineering unit calculations, log data and create exportable data files.

With the multiple inputs option installed, the 5000 Series provides simultaneous monitoring of up to six thermocouple or three RTD channels.

On single input models, an optional board may be installed which provides enhanced alarm functions as well as a scalable, linearized 4-20ma/0-10V analog output.

Multiple Inputs

Instead of the dual alarm/analog output option, the Doric 5000 can be configured to accept up to six thermocouples or three platinum RTDs.

All active inputs can be manually selected or automatically scanned. A front panel channel indicator accompanies the displayed data. Individual limits can be assigned to each channel. A built-in 5A rated form-C relay is energized whenever the limit on the selected channel is exceeded.

Analog Output

Analog output capability is also available in combination with the dual alarm option. A linearized output (4-20mA or 0-10V) with fully adjustable zero and span allows the instrument to serve as an indicating transmitter for a proportional controller, high-level input to a PC-based data converter or other recording device.

Dual Alarms

With the dual alarm option installed, the Doric 5000 can be configured to perform on/off control functions as well as process monitoring. Setpoints can be set for high, low or deviation. In addition, hysteresis (deadband) and delay can be programmed into each setpoint. Alarm conditions can be programmed for manual acknowledgment or for automatic reset. The dual alarm option comes equipped with two 5A rated form-C (NO/NC) relays, one for each alarm setpoint and flashing display whenever an alarm condition exists.

 


General Specifications
Size
1/8 DIN, 1.89" (H), 3.78" (W)

Repeatability
±1 Count

Stability with Temperature
Zero: 1µV per °C
Span: 0.01%

Thermocouple Reference Junction
Internal, automatic, 0.03°C per °C, 5°C to 45°C.

Break Detection
Upscale = 50nA, unit displays OL

Stability with Time
0.8° per year

Noise Rejection
NMRR: 60dB at 50-60Hz
CMRR: 120dB at 50-60Hz
(±0.1Hz with 250 unbalance)

Overload Protection
Power leads to ground: (1500VDC or VAC RMS)
Across inputs, for one minute: T/C up to 250VDC or VAC, V+ to V-

Input Impedance
Thermocouple: 20M , exclusive of break detect current effects
RTD: 16.9 K, V+ input to 1 input

RTD Lead Wire Error
At 150µA excitation current: 40m/ of equal resistance in
V+ and V- leads, 1 of imbalance in V+ or V- leads

Point Update Rate
2 per second nominal (1° readings)
1 per second nominal (0.1° readings)

Display
4 Digit, 14-segment red or green, 0.56" height LED
plus one 0.4" green °F/°C LED

Environmental Ranges
Operating: 0° to 50°C
Storage: -40° to +65°C
Humidity: <80% RH non-condensing

Multi-input Option Accuracy
Add ±0.5°C/1°F to instrument accuracy specification
Alarm Relay Contact Rating
5A@ 120VAC (non-inductive load) Form-C

Power
100-240VAC (±10%), 50-400Hz Standard
12VDC, 24VDC 24VAC available

RS232 Serial Communications (Standard)
Type: full-duplex voltage, isolated from ground to 500 VAC.
9600 Baud, 8 bits, 1 stop bit, no parity, ASCII.

 

Thermocouple Range Table

 

1° Resolution

0.1° Resolution

Sensor Type

Range/Display

Accuracy(±)*

Range/Display

Accuracy(±)*

J

-337 to 1403°F
-205 to 762°C

1°F+.03% rdg
1°C+.03% rdg

-99.9° to 999.9°F
-99.9° to 761.8°C

0.9°
0.5°

K

-331 to 2510°F
-202 to 1377°C

1°F+.03% rdg
1°C+.03% rdg

-99.9° to 999.9°F
-99.9° to 999.9°F

0.9°
0.5°

T

-346 to 755°F
-210 to 401°C

1°F+.03% rdg
1°C+.03% rdg

-99.9° to 754.6°F
-99.9° to 401.4°F

0.9°
0.5°

E

-338 to 1835°F
-205 to 1002°C

1°F+.03% rdg
1°C+.03% rdg

-99.9° to 999.9°F
-99.9° to 999.9°F

0.9°
0.5°

R

+32 to 3216°F
0 to 1769°C

1°F+.05% rdg
1°C+.05% rdg

 

 

S

+32 to 3218°F
0 to 1770°C

1°F+.05% rdg
1°C+.05% rdg

 

 

*Accuracy ±1 digit

 

RTD Range Table

 

1° Resolution

0.1° Resolution

Sensor Type

Range/Display

Accuracy(±)*

Range/Display

Accuracy(±)*

Platinum RTD

-329 to 1585°F

0.8°,+0.03%

-99.9° to 999.9°F

0.9°

100 Omega 3-wire
(0.00385)

-200 to 863°C

0.8°,+0.03%

-99.9° to 862.6°F

0.5°

Platinum RTD

-332 to 1563°F

0.8°,+0.03%

-99.9° to 999.9°F

0.9°

100 Omega 3-wire
(0.00392)

-202 to 851°C

0.8°,+0.03%

-99.9° to 862.6°F

0.5°

*Accuracy percentage of reading +1 digit

 